ShenzhenYijiajie Electronic Co., Ltd.

The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates

Manufacturer from China
Verified Supplier
3 Years
Home / Products / Oxygen Gas Sensor /

MOX3 MOX-3 Gas Oxygen Sensor AA829-M10 O2 Battery For Medical Devices

Contact Now
ShenzhenYijiajie Electronic Co., Ltd.
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MissXu
Contact Now

MOX3 MOX-3 Gas Oxygen Sensor AA829-M10 O2 Battery For Medical Devices

Ask Latest Price
Video Channel
Brand Name :CITY
Model Number :MOX-3 MOX3 AA829-M10
Place of Origin :Britain
MOQ :1
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :311/pcs/pre
Delivery Time :3-5work days
Packaging Details :canned
Typical Applications :Critical care anesthesia
Operating Temperature Range :-20°C to +50°C
Operating Pressure Range :0.5 Bar to 2.0 Bar
Operating Humidity Range :0% to 99% RH non-condensing
Long-Term Ouput Drift in 100% O2 :< 5% signal loss/year
Recommended Storage Temperature :-10°C to +40°C
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Product Description:

MOX-3 MOX3 AA829-M10 Oxygen Gas sensor Oxygen Battery For Medical Devices

Features:

The purpose of this document is to present the performance specification of the MOX3 oxygen gas sensor.

This document should be used in conjunction with the Operating Principles (OP04) and the Product Safety Datasheet (PSDS 4).

The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture.

Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP04).

CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.
Intended Use
These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, neonatal incubators, and general oxygen monitors.

Specifications:

Operating Principle Partial pressure electrochemical
Output 9 mV to 13 mV in 210 mBar O2
Measurement Range 0 mBar to 1500 mBar O2
Response Time (T90)* <15 s (air to 100% O2)
Baseline Offset* <200 μV
Linearity Linear 0% to 100% O2

MOX3 MOX-3 Gas Oxygen Sensor AA829-M10 O2 Battery For Medical Devices

Inquiry Cart 0