ShenzhenYijiajie Electronic Co., Ltd.

The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates

Manufacturer from China
Verified Supplier
3 Years
Home / Products / Gas Sensor /

4HSC Electrochemical Hydrogen Sulfide (H2S) Gas Sensor

Contact Now
ShenzhenYijiajie Electronic Co., Ltd.
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MissXu
Contact Now

4HSC Electrochemical Hydrogen Sulfide (H2S) Gas Sensor

Ask Latest Price
Video Channel
Brand Name :CITY
Model Number :4HSC
Place of Origin :Britain
MOQ :1
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :311/pcs/pre
Packaging Details :canned
Delivery Time :3-5work days
Operating Principle :3-electrode electrochemical
Measurement Range :0-100 ppm
Maximum Overload :500 ppm
Filter :None
Sensitivity :0.7 ± 0.15 μA/ppm
Response Time (T90) :20 Seconds at 20OC
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Product Description:

4HSC Electrochemical Hydrogen Sulfide (H2S) Gas Sensor

Features:

CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is

important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into

instruments, and operation.

When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is

fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.

Cross Sensitivity Table

Whilst CiTiceLs are designed to be highly specific to the gas they are intended to measure, they will still respond

to some degree to various other gases. The table below is not exclusive and other gases not included in the table

may still cause a sensor to react.

IMPORTANT NOTE : The cross sensitivity data shown below does not form part of the

product specification and is supplied for guidance only. Values quoted are based on

tests conducted on a small number of sensors and any batch may show significant

variation. For the most accurate measurements, an instrument should be calibrated

using the gas under investigation.

Specifications:

Recommended Load Resistor 5 Ω
Bias Voltage Not required
Housing Material Noryl 110
Weight 5 g (approx.)
Orientation Any

4HSC Electrochemical Hydrogen Sulfide (H2S) Gas Sensor