Add to Cart
ZE14-O3 Ozone Gas Sensors Anti-Water Vapor Interference No Poisoning
ZE14-O3 electrochemical ozone module is a general-purpose, miniaturized module. The electrochemical principle is used to detect O3 in the air, which has good selectivity and stability. Built-in temperature sensor for temperature compensation; at the same time, it has digital output and analog voltage output, which is convenient to use. ZE14-O3 is a general-purpose gas module designed and manufactured by closely combining mature electrochemical detection technology with sophisticated circuit design.
Datasheet:
Working voltage | 5±0.5V DC |
Warm-up time | 30 seconds |
Response time | ≤30 seconds |
Recovery time | ≤30 seconds |
Range | 0~100ppm |
Resolution | 0.1ppm |
Working temperature | -10℃~65℃ |
Working humidity | 15%RH-90%RH (non-condensing) |
Storage temperature | -20℃~65℃ |
Service life | 3-5 years (in air) |