Add to Cart
The sensor has a high level of repeatability, with a 1%F.S rating. This means that measurements taken by the sensor have a low level of variance, ensuring consistent results every time. The sensor also has an output impedance of 30KΩ, making it suitable for use with a wide range of medical equipment setups.
Our Medical Air Flow Sensor has a zero drift of 0.5%F.S, which ensures that readings taken by the sensor are accurate and reliable. This is an important feature in medical equipment, where precision and accuracy are critical.
The accuracy of our Medical Air Flow Sensor is rated at 2-2.5%F.S. This means that the sensor is able to measure air flow within a range of 2-2.5% of the full scale (F.S) of the sensor. The sensor is suitable for use in a wide range of medical applications, including ventilators, oxygen concentrators, and anesthesia machines.
The sensor is compact and easy to install, with tube packing for added convenience. It has a flow rate range of 0-6 SLPM, making it suitable for a wide range of medical applications. With its high level of accuracy, precision, and reliability, our Medical Air Flow Sensor is an essential component for any medical equipment setup that requires accurate and reliable air flow measurement.
This product is an air flow sensor, designed for measuring the flow of air in medical equipment. It has an accuracy of 2-2.5%F.S and a working temperature range of 0-50℃. The analog voltage output is 1-5V, and the dimensions are 50*27*26mm. The repeatability is 1%F.S, making it a reliable choice for accurate air flow measurements.
Technical Parameter | Value |
---|---|
Accuracy | 2-2.5%F.S |
Repeatability | 1%F.S |
Zero drift | 0.5%F.S |
Working temperature | 0-50℃ |
Output impedance | 30KΩ |
Storage temperature | 20-70℃ |
Range | 0-20SLM |
Analog voltage output | 1-5V |
Working current | 20mA |
Resolution | 0.1 |
This product is a medical flow sensor equipped with a tube packing, which can accurately measure and monitor the flow rate of gas. It uses a transducer to convert the flow rate into analog voltage output, with a range of 0-20SLM and a resolution of 0.1. The accuracy is 2-2.5%F.S, repeatability is 1%F.S, and zero drift is 0.5%F.S. It can work within a temperature range of 0-50℃, and has a storage temperature of 20-70℃. The output impedance is 30KΩ, and the working current is 20mA.
The TC TC5008-01-L060-AE-R4-P3 Medical Air Flow Sensor is ideal for a wide range of applications in the medical industry. One of the primary applications of this device is in respiratory therapy equipment. The device can be used to measure the flow of air in ventilators and nebulizers, ensuring that patients receive the right amount of oxygen. The device can also be used in anesthesia machines, where it can accurately measure the flow of air and anesthetic gases.
Another application of the TC TC5008-01-L060-AE-R4-P3 Medical Air Flow Sensor is in oxygen concentrators. This device can be used to measure the flow of air in oxygen concentrators, ensuring that the proper amount of oxygen is delivered to patients. The device can also be used in CPAP machines, where it can measure the flow of air and ensure that patients receive the right amount of pressure to keep their airways open during sleep.
The TC TC5008-01-L060-AE-R4-P3 Medical Air Flow Sensor is also suitable for use in laboratory equipment. For example, the device can be used in gas chromatography systems to measure the flow of carrier gases. The device can also be used in mass spectrometers, where it can accurately measure the flow of gases through the instrument.
This device is also ideal for use in industrial applications. For example, the device can be used in gas flow measurement systems for tube packing. The device can accurately measure the flow of gas through the tubes, ensuring that the proper amount of gas is delivered to the process.
In summary, the TC TC5008-01-L060-AE-R4-P3 Medical Air Flow Sensor is a highly accurate and reliable device that has a wide range of applications in the medical, laboratory, and industrial fields. With a range of 0-20SLM and a compact size of 50*27*26mm, this device is suitable for a variety of scenarios where precise air flow measurement is critical, such as measuring 6 SLPM.
Our Medical Air Flow Sensor product comes with comprehensive technical support and services to ensure smooth operation and performance. Our experienced team of technical experts is available to provide assistance with installation, calibration, and troubleshooting. We also offer regular maintenance and repair services to keep your equipment in top condition and extend its lifespan. In addition, we provide training and educational resources to help you optimize the use of our product and improve patient care.
Q: What is the brand name of the Medical Air Flow Sensor?
A: The brand name of the Medical Air Flow Sensor is TC.
Q: What is the model number of the Medical Air Flow Sensor?
A: The model number of the Medical Air Flow Sensor is TC5008-01-L060-AE-R4-P3.
Q: Where is the Medical Air Flow Sensor manufactured?
A: The Medical Air Flow Sensor is manufactured in China.
Q: What is the purpose of the Medical Air Flow Sensor?
A: The Medical Air Flow Sensor is used to measure the flow of air in medical equipment.
Q: What is the accuracy of the Medical Air Flow Sensor?
A: The accuracy of the Medical Air Flow Sensor is ± 5% of the measured value.