Warranty & Lifespan | Warranty Period | 3 - year warranty |
Expected Operating Life | Operates for over 36 months until output reaches 85% of original at 20.9% O₂; Output change < 2% over 3 months | |
Response Time | t90 | < 15 seconds (e.g., for 20.9% to 0% O₂ change with 47W load resistor) |
Environmental Resistance | Humidity Resistance | < 0.7% humidity affect; Continuous operation: 5 - 95% rh (non - condensing); Short - term: Up to 99% rh (non - condensing) |
CO₂ Sensitivity | < 0.1% | |
Pressure & Temperature Dependence | Good performance in varying pressure conditions; Ideal for safety apps (vs partial pressure sensors) | |
Measurement Range | Oxygen Concentration | 0.1 - 20.9% O₂ |
Output Characteristics | Output Current (22℃, 20.9% O₂) | 55 - 85 μA |
Zero Current Output (0% O₂, 99.99% N₂, 22℃) | < 2.5 μA | |
Linearity | 0.6% O₂ deviation at 10% O₂ | |
Output Drift | < 1% change in 3 months | |
Physical Specifications | Size | Diameter: 20mm; Overall dimensions: 17.4 mm x 20.3 mm |
Application Scenarios | Safety (mines, confined spaces, etc.); Potential medical gas - related equipment (with adaptation); Air quality monitoring | |
Electrical & Mechanical | Replacement & Soldering | Plug - in for hand - held gas detectors using O2 - A3; Not recommended to solder pins; Pin sockets available via Andon distributors |
Brand & Design | Technology & Advantage | Capillary flow control; Lead - free, longer lifetime than lead - based sensors; Minimizes leaks, reduces mid - contract servicing; Part of Alphasense ‘D’ family, available in different sizes |