ShenzhenYijiajie Electronic Co., Ltd.

The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates

Manufacturer from China
Verified Supplier
3 Years
Home / Products / Gas Sensor /

7HCN Hydrogen Cyanide (HCN) Gas Sensor Part Number: AJ702-400 Repeated Or Continuous Exposures Will Result In Significant Output Drift And Shortened Operating Life

Contact Now
ShenzhenYijiajie Electronic Co., Ltd.
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MissXu
Contact Now

7HCN Hydrogen Cyanide (HCN) Gas Sensor Part Number: AJ702-400 Repeated Or Continuous Exposures Will Result In Significant Output Drift And Shortened Operating Life

Ask Latest Price
Video Channel
Model Number :7HCN
MOQ :1
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :3-5 work days
Operating Principle :3-electrode electrochemical
Measurement Range :0 - 100 ppm HCN
Sensitivity* :0.10 ± 0.02 μA/ppm
Response Time (T90)* :<200 Seconds at 20°C
Resolution :0.5 ppm
Recommended Load Resistor :10 Ω
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

7HCN Hydrogen Cyanide (HCN) Gas Sensor Part Number: AJ702-400 Repeated Or Continuous Exposures Will Result In Significant Output Drift And Shortened Operating Life

IMPORTANT NOTE:

Connection should be made via PCB sockets
only. Soldering to the pins will seriously damage
your sensor and invalidate the warranty.

Poisoning:

CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important
that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments
and operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is
fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.

Cross Sensitivity Table:

Whilst CiTiceLs are designed to be highly specific to the gas they are intended to measure, they will still respond
to some degree to various other gases. The table below is not exclusive and other gases not included in the table
may still cause a sensor to react.

Weight 17 g
Operating Temperature Range -20°C to +50°C
Recommended Storage Temp 0°C to 20°C
Operating Pressure Range Atmospheric ± 10%
Operating Humidity Range 15 - 90% RH non-condensing
Expected Operating Life Two years in air
Storage Life 6 months in CTL container
Bias Voltage Not Required

7HCN Hydrogen Cyanide (HCN) Gas Sensor Part Number: AJ702-400 Repeated Or Continuous Exposures Will Result In Significant Output Drift And Shortened Operating Life

Inquiry Cart 0