ShenzhenYijiajie Electronic Co., Ltd.

The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Gas Sensor /

AC400-R00A-CIT Electrochemical Hydrogen Sulfide (H2S) Analogue Gas Sensor For Hydrogen Sulfide Gas Analyzer

Contact Now
ShenzhenYijiajie Electronic Co., Ltd.
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MissXu
Contact Now

AC400-R00A-CIT Electrochemical Hydrogen Sulfide (H2S) Analogue Gas Sensor For Hydrogen Sulfide Gas Analyzer

Ask Latest Price
Video Channel
Model Number :AC400-R00A-CIT
MOQ :1
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :3-5work days
Measurement Range :0.5 ppm H2S to 200 ppm H2S
Maximum Overload :500 ppm
Onboard Filter :None
Sensitivity* :175 nA/ppm ±35 nA/ppm
T90 Response Time* :Typically < 30 seconds
Recovery Time* (from 200 ppm to <4 ppm) :< 180 seconds
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

AC400-R00A-CIT Electrochemical Hydrogen Sulfide (H2S) Analogue Gas Sensor For Hydrogen Sulfide Gas Analyzer

Document Purpose
The purpose of this document is to present the performance specification of the 1series 1H2S hydrogen sulfide gas sensor.
This document should be used in conjunction with the 1H2S Characterisation Note, the Operating Principles (OP08), and the Product Safety Datasheet (PSDS 5).
For guidance on sensor performance outside of these limits, please refer to the 1H2S Characterisation Note.
Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP08).

Poisoning
Gas sensors are designed for operation in a wide range of environments and harsh conditions. However, it is
important that exposure to high concentrations of solvent vapours is avoided during 1) storage, 2) fitting into
instruments and 3) operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is
fitted.
Do not glue directly on or near the sensor as the solvent may cause crazing of the plastic.

Baseline Offset* (in clean air) < ±0.5 ppm H2S equivalent
Baseline Shift (-40°C to 60°C) < ±3 ppm H2S equivalent
Repeatability* < ±5% of measured value
Linearity* (0 ppm H2S to 200 ppm H2S) Linear ±5%
Recommended Load Resistor 5 Ω to 10 Ω
Weight < 5 g
Outer Plastic Body Material Modified PPO
O-ring Material FKM75 ±5 shore A