Add to Cart
NAP-50A N50A Gas Alarm Japan Catalytic Combustion Sensor For Various Gas Concentration Meters
NAP-50A is a miniature & low power consumption type of NAP-2A, and is mainly used for gas detectors. Compared to
NAP-55A, NAP-50A has a lower alcohol sensitivity to eliminate false alarms caused by alcohol, thus more reliable gas
detectors can be produced with NAP-50A. The following are the basic characteristics but it is recommended to refer to
the individual user’s manual for further information. See NAP-2A for measuring circuit for sensor evaluation.
Supply voltage | DC 2.5±0.25‚u AC 2.5±0.25‚u (r.m.s. 50∼60Hz) |
Current (When 2.5V is applied) | DC 150-170mA AC 150-170mA(r.m.s. 50∼60Hz) |
Ambient Temperature | In operation -10∼+50°C In storage -10∼+50°C |
Ambient humidity | In operation 95%RHor less In operation 99%RHor less(No dew condensation) |
Output in air | -35∼+35mV |
Methane 3000ppm | 10∼16mV |
Iso-butane 1400ppm | 9∼14mV |
Hydrogen 1400ppm | 7∼12mV |