ShenzhenYijiajie Electronic Co., Ltd.

The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Oxygen Gas Sensor /

MOX1 MOX-1 AA829-210 Oxygen Gas Sensor for Ventilator Anesthesia Machine and Oxygen Concentration Monitorin

Contact Now
ShenzhenYijiajie Electronic Co., Ltd.
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MissXu
Contact Now

MOX1 MOX-1 AA829-210 Oxygen Gas Sensor for Ventilator Anesthesia Machine and Oxygen Concentration Monitorin

Ask Latest Price
Video Channel
Model Number :MOX1 MOX-1
MOQ :1
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :3-5work days
Price :Negotiable
Supply Ability :5000PCS
Packaging Details :Standard packaging
Place of Origin :USA
Operating Principle :Partial pressure electrochemical
Output :9 mV to 13 mV in 210 mBar O2
Measurement Range :0 mBar to 1500 mBar O2
Response Time (T90) :<15 s (air to 100% O2)
Baseline Offset :<200 μV
Linearity :Linear 0% to 100% O2 (See Note1)
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

MOX1 MOX-1 AA829-210 Oxygen Gas Sensor for Ventilator Anesthesia Machine and Oxygen Concentration Monitorin

Features:

  • Wide measurement range: It can measure oxygen partial pressure from 0 mbar to 1500 mbar, corresponding to an oxygen concentration range of 0% - 100% vol. O2.
  • Fast response: The response time (t90) is less than 15 seconds (from air to 100% O2).
  • Good linearity: It has a linear output from 0% to 100% O2, which meets the requirements of ISO 80601 - 2 - 55.
  • Stable baseline: The baseline offset is less than 200 μV.
  • Temperature compensation: The temperature compensation is less than 2% O2 equivalent in the range of 0 °C to 40 °C.
  • Wide operating temperature range: It can work in the temperature range of -20 °C to +50 °C.
  • Wide operating pressure range: The operating pressure range is 0.5 bar to 2.0 bar.
  • High - humidity resistance: It can operate in an environment with a humidity range of 0% to 99% rh (non - condensing).
  • Low long - term output drift: In 100% O2, the long - term output drift is less than 5% signal loss per year.

Uses:

The MOX1 oxygen sensor is designed to monitor the partial pressure of oxygen in anesthesia (not including xenon), critical care, neonatal incubators, and general oxygen monitors.

Output 9 mv to 13 mv in 210 mbar O2
Measurement Range 0 mbar to 1500 mbar O2
Response Time (t90) < 15 s (air to 100% O2)
Baseline Offset < 200 μV
Temperature Compensation < 2% O2 equivalent (0 °C to 40 °C)
External Load Resistor 10 kΩ minimum
Connector 3 - pin Molex header (Molex 22 - 29 - 2031)
Housing Material White ABS
Weight 39 g (nominal)
Operating Temperature Range - 20 °C to + 50 °C
Operating Pressure Range 0.5 bar to 2.0 bar
Operating Humidity Range 0% to 99% rh (non - condensing)
Long - term Output Drift in 100% O2 < 5% signal loss/year
Recommended Storage Temperature - 10 °C to + 40 °C

MOX1 MOX-1 AA829-210 Oxygen Gas Sensor for Ventilator Anesthesia Machine and Oxygen Concentration Monitorin