ShenzhenYijiajie Electronic Co., Ltd.

The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates

Manufacturer from China
Verified Supplier
3 Years
Home / Products / Gas Sensor /

SGX-4CO Industrial Carbon Monoxide (CO) Sensor Electrochemical Gas Sensor Two-year Life Range 0 – 2000 ppm

Contact Now
ShenzhenYijiajie Electronic Co., Ltd.
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MissXu
Contact Now

SGX-4CO Industrial Carbon Monoxide (CO) Sensor Electrochemical Gas Sensor Two-year Life Range 0 – 2000 ppm

Ask Latest Price
Video Channel
Model Number :SGX-4CO
MOQ :1
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Delivery Time :3-5work days
Range :0 – 2000 ppm
Output Signal :Output Signal
Typical Baseline Range :±2 ppm CO equivalent
Filter Capacity :>20 000 ppm Hours
T90 Response Time :< 30 sec
Maximum Overload :5000 ppm
Linearity :Linear up to 2000ppm
Repeatibility :< ±2 CO equivalent
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

SGX-4CO Industrial Carbon Monoxide (CO) Sensor

OUTLINE:
All dimensions are in mm
All tolerances are ±0.15mm

IMPORTANT NOTES:
1) Do not glue or solder to the connector pins as this may damage the sensor and thereby
invalidate the warranty, please use PSB sockets.
2) Details on recommended connector pins can be found in the Frequently Asked Questions
within the Gas Sensor section of the SGX website.
3) All performance specifications are based upon the following environmental conditions:
20°C, 50% relative humidity, 101kPa.
4) Cross Sensitivity Data is for information only. Calibration is recommended with target gas
as the accuracy of calibration and measurement cannot be ensured.
5) The cross sensitivities are including but not limited to the gases stated in the table. It may
respond to other gases.
6) The cross sensitivities may fluctuate between ± 30% and may differ from batch to batch or
across sensor’s life time.
7) The device is designed to be RoHS compliant.
8) Poisoning - sensors are designed to operate in a wide range of harsh environments and
conditions. However, it is important that exposure to high concentrations of solvent vapours
is avoided, both during storage, fitting into instrument and operation.
9) When using sensors on printed circuit boards (PCB’s), degreasing agents should be used
prior to the sensor being fitted.

Recommended Load Resistor 10 ohms
Resolution (depend on electronic) < 0.5 ppm typical
Temperature Range -30°C to +50°C
Pressure Range 800 to 1200 mbar
Operating Humidity Range 15% to 90% RH
Long Term Output Drift < 5% per annum
Recommended Storage Temp 0°C to 20°C
Expected Operating Life > 24 months in air

SGX-4CO Industrial Carbon Monoxide (CO) Sensor Electrochemical Gas Sensor Two-year Life Range 0 – 2000 ppm