ShenzhenYijiajie Electronic Co., Ltd.

The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates

Manufacturer from China
Verified Supplier
4 Years
Home / Products / Gas Sensor /

4AN AI200-800 Electrochemical Three Electrode Acrylonitrile (C3H3N) Gas Sensor For Changes Acrylonitrile Concentration

Contact Now
ShenzhenYijiajie Electronic Co., Ltd.
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MissXu
Contact Now

4AN AI200-800 Electrochemical Three Electrode Acrylonitrile (C3H3N) Gas Sensor For Changes Acrylonitrile Concentration

Ask Latest Price
Video Channel
Model Number :4AN
Place of Origin :USA
MOQ :1PCS
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :5000PCS
Delivery Time :5-8 work days
Packaging Details :Standard packaging
Measurement Range :0 ppm to 80 ppm C3H3N
Sensitivity :250 nA/ppm ±100 nA/ppm
Response Time :<120 seconds at 20°C
Recommended Load Resistor :10 Ω
Bias Voltage :300 mV
Weight :5 g
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

4AN AI200-800 Electrochemical Three Electrode Acrylonitrile (C3H3N) Gas Sensor For Changes Acrylonitrile Concentration

Document Purpose:


The purpose of this document is to present the performance specification of the 4AN CiTiceL.
This document should be used in conjunction with Operating Principles (OP09) and the Product Safety Datasheet (PSDS 2).
The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture. For guidance on sensor performance outside of these limits, please refer to the Operating Principles.
Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles.

APPLICATION NOTE:

Not suitable for repeated or continuous exposures. 4AN is designed for life safety applications where the sensor is only exposed to gas occasionally. Repeated or continuous exposures will result in significant output drift and shortened operating life. If the sensor is exposed to gas, functionality and performance characteristics should be checked to confirm that the sensor is still performing within acceptable limits.

Category

Specifications

MEASUREMENT - Principle: 3-electrode electrochemical
- Measuring Range: 0 ppm to 80 ppm
- Filter: None
- Sensitivity: 250 nA/ppm ± 100 nA/ppm
- Response Time: Less than 120 seconds at 20°C
- Baseline Drift (in clean air): -0.5 ppm to +1 ppm (acrylonitrile equivalent)
ELECTRICAL - Recommended Load Resistance: 10Ω
- Bias Voltage: 300 mV
MECHANICAL - Housing Material (housing and main body): ABS
- Weight: 5 g
- Mounting Direction: Any
ENVIRONMENTAL

- Operating Temperature Range: -20°C to +50°C
- Recommended Storage Temperature: 0°C to 20°C
- Operating Pressure Range: Atmospheric pressure ±10%
- Operating Humidity Range (exposure to extreme humidity will reduce sensor performance):

15% to 90% relative humidity (RH) under non-condensing conditions

LIFETIME - Expected Service Life (in air): 2 years

4AN AI200-800 Electrochemical Three Electrode Acrylonitrile (C3H3N) Gas Sensor For Changes Acrylonitrile Concentration

Inquiry Cart 0